Condition: New

Manufacturer Part Number: Does Not Apply

Type: Truck Air Conditioner

Fuel: Electricity

Power: 800W 

Cooling Capacity: 1000-3000w

Material: Plastic + Metal

Color: Red + White

Brand: Unbranded

 

Note:

Installation Manual Is Included

Professional Installation Is Highly Recommended

 

Features:

· 100% Brand New and High Quality, Durable

· High Cooling Capacity & Reliable Performance Suitable for Most Place in the World

·  Battery Driven, save Fuel Consumption and save Space with Compact Design
· Stream Line Design to Apply All Kinds of Van & Mini Bus

· After Strictly Water Pouring Test, No Water Penetration
· Environment Friendly

· Light and Thin Appearance, Saving Space

· Double Insulation,Noise Reduction,More Comfortable

Specification:

12v

Current (a):60a-80a

Rated Power:800W 

Cooling Capacity:1000w-3000w

Refrigerant:r134a 600g (Not Include)

Oil:90ml-120ml Poe68 

Circulating Air Volume: 600m³/H

Range of Speed:1000-3000

Outdoor Unit Size:660*490*210 (Mm)

Indoor Unit Size:450*330*160 (Mm)

Manual Measurement, There Is a Certain Error, for Reference Only

 

Package Includes:

1 X Air Conditioner Set, 1x Product Manual

 

 

Electric Air Conditioner Usage Instructions

 

Panel, Remote Control Operation 

1." Power ": Short Press to Start, Long Press to Shut down. Long Press in 10 Seconds in the State of Shutdown, to Restore the Factory Settings.

 

2.“ Air Volume”: “+” Key Increase Air Supply and the Under Voltage Protection Value. “-” Key Decrease Air Supply and the Under Voltage Protection Value.

 

3.“Ac Mode”:Circular Long Press by One Second Switching Mode: Air Supply, Manual, Automatic, Strong; 10 Seconds Go into the Under Voltage Value and the Under Voltage Recovery Value Adjustment State. After Finishing Adjusting the Under Voltage Value, It Will Automatically Memory and Exit After 5 Seconds.

 

4. “Temperature”: “+”Key Increase Temperature and the Under Voltage Protection Value. “-” Key Decrease Temperature and the Under Voltage Protection Value.

Under Voltage Protection Value and Under Voltage Recovery Value Adjustment: Long Press the Mode Key. 10 Seconds to Go into the Adjustment Interface. Adjust the Wind Speed plus and Minus Key to Set the Under Voltage Protection Value. Adjust the Temperature plus and Minus Key to Set the Under Voltage Recovery Value.

 

  • “Strong” Key: Press to Enter the Strong Refrigeration Model.

 

6.“ Energy Saving” Key: Press to Enter the Energy Saving Refrigeration Mod

 

7. Full Frequency Conversion Energy Saving Function: the Temperature Sensor Sends out the Outlet to Induce the Outlet Temperature, Automatically Adjusts the Speed of the Compressor, and Realizes Energy Saving and Electricity Saving.

 

Attention

1. When the Equipment Opens, the Air Outlet Temperature Is Displayed by Default. the Outlet Temperature Setting Is the Standard of the Compressor Shutdown. When the Outlet Temperature Is less than or Equal to the Setting Temperature, the Compressor Will Stop Working. After the Compressor Stops Working, If the Outlet Temperature Rises up to 3 Degree Higher than the Setting Temperature, the Compressor Will Start and Refrigerate.

 

2. After the Equipment Starts, in some Situations, If the Compressor Need to Be Restarted After Closing, the Equipment Will Automatically Control to Wait for 30 Seconds to Protect the Compressor.

 

Fault Code Description

If There Is Any Fault, the Fault Indicator Light Will Light up. All the Faults Will Cause the Compressor to Stop. Please Check the Fault Code to Identify the Specific Fault.

Project

Fault Code

Treatment

Temperature Sensor Failure

Ec

Check Whether the Sensing Line Is off or Invalid

Run High Current Protection

E-2

Check Whether the Refrigerant Is Overcharged and Whether the Fan Is Running Normally

Compressor Stall Protection

E-3

Cleaning the Air Conditioning System

Undervoltage Protection

E-4

The Generator Power Is Insufficient, and the Battery Does Not Store Electricity

Poor Cooling Protection

E-5

Check Whether the Position of the Sensor Is Correct or Lack of Refrigerant

Electronic Fan Failure

E-6

Replace the Fan

Compressor Phase Loss

E-7

Check Whether the Terminal Is in Bad Contact

Temperature Protection

E-9

Lack of Refrigerant or Hot Air from the Air-conditioning Host, Change the Location of the Host to Avoid Heat Sources near the Air Inlet

 

Note: The Air Conditioner Outdoor Unit Color Is Red and White Shipped Randomly 