| The Professional Auto-range Digital Multimeter is a powerful tool for debugging circuits with high performance, high accuracy with large LCD display measuring DCV, ACV, DCA, ACA, Resistance, Capacitance, Frequency, Temperature, Duty Cycle Measurement, Triode, Diode and Continuity Test. Designed function includes: unit signal displaying, relative value measuring, AUTO/MANUAL range switch, auto power off and warning function, auto negative polarity indication, overload protection, etc. This multimeter is most suitable for use on production lines or lab, R & D, maintenance and repairing work.
| |
|
- Designed for field professionals
- 3 ¾ digit Large LCD Display
- With stand, auto-off and buzzer
- Low battery display indication
- Automatic negative polarity indication
- Manual and automatic ranging
- Temperature measurements (-40~1000°C)
- Full overload protection
- Perform test like DCV, ACV, DCA, ACA, Resistance, Capacitance, Frequency, Temperature, hFE, Duty Cycle, Triode, Diode and Continuity Test
- Ergonomic case with protective rubber holster
| | | - Display: 3 ¾ digit Large LCD with a max readings of 3999
- Measuring method: Dual-slope integrating A/D Converter System
- Sampling Rate: approx. 3 Times / Second
- Range Selection Method: Automatic and Manual
- Polarity: Automatic Negative Polarity Indication
- Over range indication: "OL" display
- Operating Temperature: 0 ~ 40°C; Operating Humidity: <80% RH
- Storage Temperature: -10 ~ 50°C; Storage Humidity: <80% RH
- Low battery indicator
- Power: 2 x 1.5V AAA batteries (included)
- Dimensions: 185(L) x 93(W) x 35(H) mm
- Weight: approx. 290g (including battery)
Technical Specification: Accuracy is ±(percentage of reading + number of digit) at (23±5) °C, <75% RH. DC Voltage Range | Accuracy | Resolution | 400mV | ±(0.5%+4d) | 0.1mV | 4V | 1mV | 40V | 10mV | 400V | 100mV | 1000V | ±(1.0%+4d) | 1V |
Input impedance: 400 mV range: more than 40MΩ ; other range: 10MΩ Overload protection: 1000 V DC or 750V AC peak value AC Voltage (only 400mV range has manual range) Range | Accuracy | Resolution | 400mV | ±(1.5%+6d) | 0.1mV | 4V | ±(0.8%+6d) | 1mV | 40V | 10mV | 400V | 100mV | 750V | ±(1.0%+6d) | 1V |
Input impedance: 400 mV range: more than 40 MΩ ; other range: 10 MΩ Frequency response: 750 v range: 40-100 Hz ; other range: 40-400 Hz Overload protection: 1000 V DC / 750 V AC peak value DCA Range | Accuracy | Resolution | 400uA | ±(1.0%+5d) | 0.1uA | 4000uA | 1uA | 40mA | 10uA | 400mA | 100uA | 4A | 1mA | 20A | ±(2.0%+5d) | 10mA |
Max. Measuring volt drop: 400mV under mA range, 200mV under A range. Max. input current: 20A (less than 10 sec) Overload protection: 0.5/250V fuse, 15A/250V fuse ACA Range | Accuracy | Resolution | 400uA | ±(1.5%+5d) | 0.1uA | 4000uA | 1uA | 40mA | 10uA | 400mA | 100uA | 4A | 1mA | 20A | ±(2.0%+10d) | 10mA |
Max. Measuring volt drop: 400mV under mA range, 200mV under A range. Max. input current: 20A (less than 10 sec) Overload protection: 0.5/250V fuse, 15A/250V fuse Frequency response: (40~100)Hz under 20A range, (40~400) Hz at other range. Resistance Range | Accuracy | Resolution | 400Ω | ±(0.8%+5d) | 0.1Ω | 4kΩ | ±(0.8%+2d) | 1Ω | 40kΩ | 10Ω | 400kΩ | 100Ω | 4MΩ | 1kΩ | 40MΩ | ±(1.2%+5d) | 10kΩ |
Overload protection: 250V DC/AC Peak Value Open circuit voltage: 400 mV Capacitance Range | Accuracy | Resolution | 4nF | ±(0.5%+20d) | 1pF | 40nF | ±(3.5%+8d) | 10pF | 400nF | 100pF | 4uF | 1nF | 40uF | 10nF | 200uF | ±(5.0%+8d) | 100nF |
Overload protection: 250V DC/AC Peak Value Frequency Range | Accuracy | Resolution | 10Hz | ±(0.5%+4d) | 0.01Hz | 100Hz | 0.1Hz | 1000Hz | 0.1Hz | 10kHz | 1Hz | 100kHz | 10Hz | 1MHz | 100Hz | 30MHz | 1kHz |
NPUT SENSOR: 0.7V Overload protection: 250V DC/AC Peak Value Diode and Continuity Test Range | Description | Test Condition | Diode | Display read approx.forward voltage of diode | Forward DC Current approx 0.5mA Reversed voltage approx. 1.5V | Buzzer | Buzzer sounds if resistance between terminals V/Ωand COM is less than (50± 10) Ω | Open circuit voltage:0.5V |
Overload Protection: 250 V DC/AC peak value Warning: Do not input Voltage at the range for safety hFE Range | Description | Test Condition | NPN or PNP | 0 ~ 1000 | Basic Current is Approx. 15 µA. Vce is approx. 4.5V |
Temperature Range | Description | Test Condition | -40 - 1000 °C | < 400 °C ± (0.8% + 4) =400 °C ± (1.5% + 15) | 1 °C |
Thermocouple: K Type Warning: Do not input any voltage at this range
Accessories included:
- 1 x Auto/Manual Range Digital Multimeter
- 1 x pair of Test Leads
- 1 x K-Type Thermocouple Wire
- 2 x 1.5V AAA batteries (included)
- 1 x Non-slip Rubber Protection Cover
- 1 x Instruction Manual
- Standard Factory Package
- Warranty: 2 years warranty
All our products are manufactured under the strict quality control guidelines established by EN ISO9001-2000 Standard
|
|